Etiqueta de plano Material Clase λ Densidad Se usa en
INSULTERM 600 INSULTERM 600 The only proprietary material in the verified set. Encapsulates the steel frame and building services, forming a low-density monolithic element. Spray-applied thermal-acoustic conglomerate 0.138 W/m·K 600 kg/m³ D.01 · D.02 · D.03 · D.04 · D.05
Placner Placner ribbed steel sheathing 0.3 mm base sheet, Z200 zinc coating as standard, Z275 available and specified for coastal and marine exposure. Panel 600 × 2,500 mm (1.5 m²). Cold-rolled galvanised steel sheet, V-form ribs — — D.01 · D.02
C140 Cold-formed galvanised C-stud, 140 mm Load-bearing walls and façades. Cold-formed galvanised steel — — D.02 · D.03
C90 Cold-formed galvanised C-stud, 90 mm Partitions. Cold-formed galvanised steel — — D.04 · D.05
Joist 250–400 Cold-formed steel joist, 250 / 300 / 350 / 400 mm Depth range only. Span capacity is not stated — selection tables in preparation. Cold-formed galvanised steel — — D.07 · D.08 · D.09
Rock wool Mineral wool The cold side of the stud cavity in D.02, and the acoustic core of D.03, D.04 and D.05: 50 mm in D.02 and D.03, 40 mm in D.04 and D.05. Figures are ISOVER Alphatoit, an unfaced rigid rock wool panel: λD 0,039 W/m·K to EN 12667 / EN 12939, declared thermal resistance RD 1,25 m²·K/W at 50 mm to EN 13162, designation MW-EN 13162-T5-DS(70,90)-WS-MU1-CS(10)50-TR10-AFr50. Also declared: reaction to fire Euroclass A1 to EN 13501-1 — a reaction-to-fire class for the material, NOT a fire resistance for any build-up, which remains in test; compressive strength at 10% deformation 50,0 kPa to EN 826; short-term water absorption below 1 kg/m² to EN 1609; dimensional stability below 1% to EN 1604; airflow resistance above 5 kPa·s/m² to EN 29053; specific heat approximately 800 J/(kg·K). Density is not stated on the datasheet and is left blank rather than inferred. Mineral fibre insulation 0.039 W/m·K — D.02 · D.03 · D.04 · D.05
Pladur Pladur plasterboard Internal lining to the walls, and the ceiling finish under the floor and the roof. Gypsum board — — D.02 · D.03 · D.04 · D.05 · D.07 · D.08
Aquapanel Aquapanel cement board Must not be substituted with standard plasterboard on the parapet. Cement-bonded board — — D.01
Monocapa Monocapa render External finish, and the finish to the terrace face of the parapet. Single-coat mineral render — — D.01 · D.02
XPS Extruded polystyrene 50 mm standard; reduced to 30 mm in the D.08-C Canary Islands variant. Rigid foam insulation — — D.08
Omega Omega channel Furring profile carrying the lining, with a service void behind it. In D.03 the two decoupled channels form the mass–spring–mass arrangement. Cold-formed galvanised steel — — D.02 · D.03 · D.04 · D.05
Glass wool Glass mineral wool Within the joist depth. The product is not yet identified, so λ and density stay blank until its datasheet is supplied. Mineral fibre insulation — — D.07 · D.08
OSB OSB board Structural decking over the joists. In D.08 a second board over the XPS carries the lightweight concrete to falls. Oriented strand board — — D.07 · D.08
Lightweight concrete Lightweight concrete The floor diaphragm in D.07, cast on a trapezoidal steel deck left as permanent formwork. Laid to falls in D.08. Lightweight concrete — — D.07 · D.08
Chapa colaborante Trapezoidal steel deck A 1 mm composite deck with trapezoidal ribs 50 mm high and 70 mm apart, left in place as permanent formwork and cast into the lightweight concrete. Trapezoidal profiled steel sheet — — D.07
Bituminous membrane Self-protected bituminous membrane The waterproofing layer of the non-trafficable roof. Bituminous waterproofing membrane — — D.08
Tile adhesive Tile adhesive Bonds the wall tiling direct to the sprayed INSULTERM 600 in D.05, and the floor finish in D.07. Cement-based adhesive — — D.05 · D.07
Ceramic tile Ceramic tile Wall tiling in D.05, floor finish in D.07. Ceramic — — D.05 · D.07
Knauf channel Knauf ceiling channel Carries the plasterboard ceiling below the joists. Steel ceiling suspension profile — — D.07 · D.08

The complete 22-row register lives in the source document (SOLID SYSTEM — Construction Details Catalog). The rows below are the materials named in the build brief and in the D.01–D.08 layer schedules, with λ and density stated only where a source document states them. The remaining rows, and the λ and density values left null here, arrive with the signed structured detail data — open item 4.