Material register

Every material used across the nine details, with its class, thermal conductivity and density where the source document states them.

19 of 22 entries published
Drawing label Material Class λ Density Used in
INSULTERM 600 INSULTERM 600 The only proprietary material in the verified set. Encapsulates the steel frame and building services, forming a low-density monolithic element. Spray-applied thermal-acoustic conglomerate 0.138 W/m·K 600 kg/m³ D.01 · D.02 · D.03 · D.04 · D.05
Placner Placner ribbed steel sheathing 0.3 mm base sheet, Z200 zinc coating as standard, Z275 available and specified for coastal and marine exposure. Panel 600 × 2,500 mm (1.5 m²). Cold-rolled galvanised steel sheet, V-form ribs — — D.01 · D.02
C140 Cold-formed galvanised C-stud, 140 mm Load-bearing walls and façades. Cold-formed galvanised steel — — D.02 · D.03
C90 Cold-formed galvanised C-stud, 90 mm Partitions. Cold-formed galvanised steel — — D.04 · D.05
Joist 250–400 Cold-formed steel joist, 250 / 300 / 350 / 400 mm Depth range only. Span capacity is not stated — selection tables in preparation. Cold-formed galvanised steel — — D.07 · D.08 · D.09
Rock wool Mineral wool The cold side of the stud cavity in D.02, and the acoustic core of D.03, D.04 and D.05: 50 mm in D.02 and D.03, 40 mm in D.04 and D.05. Figures are ISOVER Alphatoit, an unfaced rigid rock wool panel: λD 0,039 W/m·K to EN 12667 / EN 12939, declared thermal resistance RD 1,25 m²·K/W at 50 mm to EN 13162, designation MW-EN 13162-T5-DS(70,90)-WS-MU1-CS(10)50-TR10-AFr50. Also declared: reaction to fire Euroclass A1 to EN 13501-1 — a reaction-to-fire class for the material, NOT a fire resistance for any build-up, which remains in test; compressive strength at 10% deformation 50,0 kPa to EN 826; short-term water absorption below 1 kg/m² to EN 1609; dimensional stability below 1% to EN 1604; airflow resistance above 5 kPa·s/m² to EN 29053; specific heat approximately 800 J/(kg·K). Density is not stated on the datasheet and is left blank rather than inferred. Mineral fibre insulation 0.039 W/m·K — D.02 · D.03 · D.04 · D.05
Pladur Pladur plasterboard Internal lining to the walls, and the ceiling finish under the floor and the roof. Gypsum board — — D.02 · D.03 · D.04 · D.05 · D.07 · D.08
Aquapanel Aquapanel cement board Must not be substituted with standard plasterboard on the parapet. Cement-bonded board — — D.01
Monocapa Monocapa render External finish, and the finish to the terrace face of the parapet. Single-coat mineral render — — D.01 · D.02
XPS Extruded polystyrene 50 mm standard; reduced to 30 mm in the D.08-C Canary Islands variant. Rigid foam insulation — — D.08
Omega Omega channel Furring profile carrying the lining, with a service void behind it. In D.03 the two decoupled channels form the mass–spring–mass arrangement. Cold-formed galvanised steel — — D.02 · D.03 · D.04 · D.05
Glass wool Glass mineral wool Within the joist depth. The product is not yet identified, so λ and density stay blank until its datasheet is supplied. Mineral fibre insulation — — D.07 · D.08
OSB OSB board Structural decking over the joists. In D.08 a second board over the XPS carries the lightweight concrete to falls. Oriented strand board — — D.07 · D.08
Lightweight concrete Lightweight concrete The floor diaphragm in D.07, cast on a trapezoidal steel deck left as permanent formwork. Laid to falls in D.08. Lightweight concrete — — D.07 · D.08
Chapa colaborante Trapezoidal steel deck A 1 mm composite deck with trapezoidal ribs 50 mm high and 70 mm apart, left in place as permanent formwork and cast into the lightweight concrete. Trapezoidal profiled steel sheet — — D.07
Bituminous membrane Self-protected bituminous membrane The waterproofing layer of the non-trafficable roof. Bituminous waterproofing membrane — — D.08
Tile adhesive Tile adhesive Bonds the wall tiling direct to the sprayed INSULTERM 600 in D.05, and the floor finish in D.07. Cement-based adhesive — — D.05 · D.07
Ceramic tile Ceramic tile Wall tiling in D.05, floor finish in D.07. Ceramic — — D.05 · D.07
Knauf channel Knauf ceiling channel Carries the plasterboard ceiling below the joists. Steel ceiling suspension profile — — D.07 · D.08

The complete 22-row register lives in the source document (SOLID SYSTEM — Construction Details Catalog). The rows below are the materials named in the build brief and in the D.01–D.08 layer schedules, with λ and density stated only where a source document states them. The remaining rows, and the λ and density values left null here, arrive with the signed structured detail data — open item 4.