The non-load-bearing internal partition, on C90 studs. At 146 mm it is the thinnest of the vertical elements after the wet-area partition, and it is the detail that appears most often on a residential floor plate.
D.04
Internal partition
Tabique interior
146 mm
Total thickness · Revision 01 · 2026-08
D.04
Internal partition
SCALE 1:10
Dashed layers sit inside the stud cavity, not in addition to it. Keyboard navigable with the arrow keys; the same data is published as a table in the layer schedule below.
Photographs
1 / 14
Layer schedule
| Layer | Material | Thickness | λ | Function |
|---|---|---|---|---|
| 1 Pladur plasterboard lining | Gypsum board | 13 mm | — | Internal finish |
| 2 Omega furring profile | Cold-formed galvanised steel | 15 mm | — | Decoupled fixing profile for the lining, with a service void |
| 3 INSULTERM 600 in stud cavity | Sprayed thermal-acoustic conglomerate | 25 mm | 0.138 W/m·K | Encapsulation |
| 4 Mineral wool in stud cavity | Rock wool | 40 mm | 0.039 W/m·K | Acoustic core ISOVER Alphatoit rigid rock wool panel, as in D.02. λD from the manufacturer's datasheet (FT_Alphatoit_ES, 14/03/2024), to EN 12667 / EN 12939. |
| 5 INSULTERM 600 in stud cavity | Sprayed thermal-acoustic conglomerate | 25 mm | 0.138 W/m·K | Encapsulation |
| 6 C90 steel stud cavity | Cold-formed galvanised steel | 90 mm | — | Framing — the cavity contains layers 3, 4 and 5 |
| 7 Omega furring profile | Cold-formed galvanised steel | 15 mm | — | Decoupled fixing profile for the lining, with a service void |
| 8 Pladur plasterboard lining | Gypsum board | 13 mm | — | Internal finish |
| Total | 146 mm |
An em dash means the source document does not state that value; it is not a zero. Cavity-contained layers are indented — they sit inside the stud depth, so the column does not sum to the total.
Calculated performance
| Property | Value | Basis |
|---|---|---|
| U-value, bridging corrected | 0.55 W/m²K | EN ISO 6946, one-dimensional steady state, with a +20% bridging correction applied as an engineering estimate. |
| Self-weight | 62 kg/m² | Mass estimate from the layers and dimensions in the source document. |
| Traditional equivalent | 89 kg/m² | Derived from the published self-weight and reduction percentage. |
| Weight reduction | −30% | Self-weight against the traditional equivalent build-up. |
| Fire resistance (EI) | Test programme in progress — contact technical department | Awaiting laboratory test report |
| Airborne sound reduction (R_A) | Test programme in progress — contact technical department | Awaiting laboratory test report |
| Impact sound (L_nw) | Test programme in progress — contact technical department | Awaiting laboratory test report |
U-values are one-dimensional steady-state calculations to EN ISO 6946. Bridging correction is applied as an engineering estimate: +20% for walls, +15% for horizontal elements. 2D numerical analysis to EN ISO 10211 is in progress; values will be updated on completion.
Not yet stated
- EIFire resistance · in test
- R_AAirborne sound reduction · in test
- L_nwImpact sound · in test
Test programme in progress — contact technical department
Weight against traditional
| Element | Solid System | Traditional | Reduction |
|---|---|---|---|
| D.04 Internal partition | 62 kg/m² | 89 kg/m² | −30% |
Where to use it
- Non-load-bearing partitions within a dwelling
- Room divisions on C90 studs
Design notes
- C90 studs are specified for partitions. C140 is used for load-bearing walls and façades.
- Services are run within the stud cavity before the lining is closed.